Roof-tank pump
Transfers water from ground tank to roof tank reliably.

Jahra
Pump installation in Subbiya depends on the private well location, tank height and distance between them. We test the pump draw from the existing well and confirm water reaches the tank without pressure loss. Copper pipes, the electric motor and all joints are checked before first run. We monitor performance to ensure consistent filling.
Subbiya houses near the Sheikh Jaber Al-Ahmad Mosque mix deep wells, ground cisterns and high roofs. Some need one pump drawing from the well to a single tank. Others need a first pump filling a ground cistern and a second pumping from ground to roof. We measure existing pipes first and choose the right motor to avoid over or under-pumping.
Subbiya is a residential area in Jahra near Sheikh Jaber Al-Ahmad Causeway, where private wells are common in both old and new houses.
Every Subbiya pump is tested by continuous flow filling three horizontal storeys from an empty tank while we record pressure at each level.
Transfers water from ground tank to roof tank reliably.
Keeps hot water at the tap without a long wait.
Sets correct cut-in and cut-out points, stops short-cycling.
Evacuates cesspits efficiently with a non-return valve fitted.
Lifts sewage from low-level units to the drainage network.
Protects basements from water accumulation via float-activated switch.
How we work

Tell us what is happening and where, and the right equipment is loaded before we arrive.

We film the line from inside and know the kind of blockage and its exact place. No guessing.

High pressure water, a machine or a drain snake, whichever the line actually needs.

The camera runs a second pass and you see the line clear with your own eyes before we leave.
Same method, same equipment. Only the size of the job changes.




Why us
Amana means trust. Someone else's home is not ours to be careless in.
Do not take our word for it. Look at the line yourself.
Breaking is the last resort, never the first step.
A blocked line does not wait for the morning.
Six governorates, 139 areas.
For buildings and complexes, servicing before the problem starts.
Restaurants, offices and complexes, not only homes.
Common questions
Need someone now? The emergency line is open any hour.
+965 9668 4964
No, because the roof is thirty metres higher and the ground tank is below. One pump will take all its strength to lift to the roof and leave the ground tank short. The correct system is a first pump filling the ground tank from the well, then a second pump from ground to roof.
High heat means the motor works over its rating or the filter is blocked. We test pressure and flow first to see if pipes are too narrow or water has sand in it. If the filter is clean and pipes are open, the motor itself may need replacing.