Tank installation
Mounting the tank on a level concrete base to protect its base from cracking

Jahra
Roof tank installation in Abdali starts with checking the roof structure and weight allowance. We choose the best position away from power lines, secure the concrete base, run inlet and outlet lines and test pressure when all connections are live.
Abdali houses have solid flat roofs but water mains are distant from some residential blocks, making a roof tank essential for steady pressure all day. We check for buried pipes before digging, and test soil acidity since seasonal moisture affects the base. The overflow outlet runs to a floor trap instead of letting water seep down the walls.
Abdali lies in Jahra governorate, a farming and residential area where flat roofs are the only space available for a roof tank.
The tank is inspected after the first fill to confirm no leaks exist at welds or joints.
Mounting the tank on a level concrete base to protect its base from cracking
Running the fill line and distribution line to floors in PPR pipe
Installing the overflow at correct slope so no water pools on the roof
Connecting the existing transfer or pressure pump and setting its switch
Fitting a brass float valve sized to the tank for accurate fill cut-off
Testing all joints under pressure before handover to confirm no leaks
How we work

Tell us what is happening and where, and the right equipment is loaded before we arrive.

We film the line from inside and know the kind of blockage and its exact place. No guessing.

High pressure water, a machine or a drain snake, whichever the line actually needs.

The camera runs a second pass and you see the line clear with your own eyes before we leave.
Same method, same equipment. Only the size of the job changes.




Why us
Amana means trust. Someone else's home is not ours to be careless in.
Do not take our word for it. Look at the line yourself.
Breaking is the last resort, never the first step.
A blocked line does not wait for the morning.
Six governorates, 139 areas.
For buildings and complexes, servicing before the problem starts.
Restaurants, offices and complexes, not only homes.
Common questions
Need someone now? The emergency line is open any hour.
+965 9668 4964
Yes, but we must sample the roof first to calculate remaining load capacity and true strength. If capacity is insufficient we recommend added timber or steel bracing under the base.
Excess water flows through an overflow outlet we install above the safe water level. This outlet runs down to a floor trap to prevent water seeping down walls and damaging the foundation.