Tank installation
Mounting the tank on a level concrete base to protect its base from cracking

Capital
Roof tank installation in Doha requires calculating the exact height needed to ensure adequate water pressure at the lowest point in your home. We choose a tank position on the roof facing the marina, run pipes through the floors and do a final pressure test after introducing water.
Modern residential and commercial buildings in Doha near Fifth Ring Road are often multi-storey and need large roof tanks to supply many flats. We measure each floor height and calculate friction loss across long pipe runs before choosing tank size. The rising main usually travels through the main internal column inside the building where it stays protected from wind and weather.
Doha sits in Kuwait governorate near Doha Port and Marina, a district of modern multi-storey buildings.
We record pressure readings at each floor level during testing because pressure drop shows where a leak is in the rising main.
Mounting the tank on a level concrete base to protect its base from cracking
Running the fill line and distribution line to floors in PPR pipe
Installing the overflow at correct slope so no water pools on the roof
Connecting the existing transfer or pressure pump and setting its switch
Fitting a brass float valve sized to the tank for accurate fill cut-off
Testing all joints under pressure before handover to confirm no leaks
How we work

Tell us what is happening and where, and the right equipment is loaded before we arrive.

We film the line from inside and know the kind of blockage and its exact place. No guessing.

High pressure water, a machine or a drain snake, whichever the line actually needs.

The camera runs a second pass and you see the line clear with your own eyes before we leave.
Same method, same equipment. Only the size of the job changes.




Why us
Amana means trust. Someone else's home is not ours to be careless in.
Do not take our word for it. Look at the line yourself.
Breaking is the last resort, never the first step.
A blocked line does not wait for the morning.
Six governorates, 139 areas.
For buildings and complexes, servicing before the problem starts.
Restaurants, offices and complexes, not only homes.
Common questions
Need someone now? The emergency line is open any hour.
+965 9668 4964
It depends on the number of flats and total height. Very tall buildings may need two tanks or a larger single tank. We calculate available pressure at the top floor based on water height in the tank.
We lay the tank horizontally instead of standing it upright, or use a narrow cylindrical tank that takes less space. If needed we tuck part of the tank into a rooftop plant room rather than the fully exposed area.