Site and depth planning
Position and depth chosen to suit the transfer pump and surface loads

Jahra
An underground tank in Salmi near the Kuwait-Iraq border faces extreme temperature swings due to desert proximity. We site the tank far from border water lines and build very tight walls with extra thermal insulation to protect tank water from heat contamination.
Salmi is a border zone in Jahra governorate near Salmi Market and the direct border, with rock-hard scorching soil. Summer temperatures reach fifty degrees Celsius so water in a surface tank heats fast, making underground storage much better for keeping water cool. We add an extra insulating membrane over the tank under the soil to reflect heat, and test the internal water temperature right after filling to confirm it stays cool.
Salmi sits in Jahra governorate on Kuwait's north-western border, a very hot zone requiring special water protection.
We test tank water temperature at full fill and record it because extreme heat can trigger algae growth.
Position and depth chosen to suit the transfer pump and surface loads
Base and walls built to carry soil pressure and full water load
Internal and external coating layers that block water movement in both directions
Inlet and outlet openings sealed with rubber collars to prevent pipe-joint leaks
Transfer pump and water-level float wired and adjusted for correct operation
Tank filled and water level watched to confirm zero leakage before backfilling
How we work

Tell us what is happening and where, and the right equipment is loaded before we arrive.

We film the line from inside and know the kind of blockage and its exact place. No guessing.

High pressure water, a machine or a drain snake, whichever the line actually needs.

The camera runs a second pass and you see the line clear with your own eyes before we leave.
Same method, same equipment. Only the size of the job changes.




Why us
Amana means trust. Someone else's home is not ours to be careless in.
Do not take our word for it. Look at the line yourself.
Breaking is the last resort, never the first step.
A blocked line does not wait for the morning.
Six governorates, 139 areas.
For buildings and complexes, servicing before the problem starts.
Restaurants, offices and complexes, not only homes.
Common questions
Need someone now? The emergency line is open any hour.
+965 9668 4964
Concrete itself tolerates heat well, but extreme heat expands water inside the tank and raises internal pressure. We use high-strength concrete and install expansion joints in walls to relieve extra pressure.
An underground tank by nature sits under soil so no extra shading is needed. But if the top cover sits close to surface we add thick sand or gravel over it for extra thermal insulation.