Fault diagnosis
Element, thermostat and wiring tested before any parts are removed

Mubarak Al-Kabeer
Electric heater repair in Funaitees requires careful inspection of the heating element and the entire electrical circuit. We check resistance with an ohmmeter and inspect connections to the main switchbox. We measure the actual voltage reaching the heater under full load. We test everything by running a complete heating cycle before leaving.
In Funaitees apartment blocks are standard, with electric heaters typically small at 30 to 50 litres in tight kitchen spaces. Electrical circuits in older buildings may be heavily loaded if several flats run heaters together. This causes voltage drop, making heaters slow or intermittent. When repairing we check total load on the sub-circuit and advise load redistribution if needed.
Funaitees lies near Mubarak Al-Kabeer governorate, a dense apartment zone with shared facilities.
We test voltage at the heater terminal before and after repair because voltage below 200V means the element will not deliver full power.
Element, thermostat and wiring tested before any parts are removed
Scaled or burnt element removed and a matched replacement fitted
Thermostat tested and adjusted or replaced if it no longer cuts off correctly
Leak located with camera; tiles are not broken unless the pipe itself is cracked
Calcium sediment drained from the tank base to restore heating capacity
Temperature and pressure confirmed in front of the customer after repair
How we work

Tell us what is happening and where, and the right equipment is loaded before we arrive.

We film the line from inside and know the kind of blockage and its exact place. No guessing.

High pressure water, a machine or a drain snake, whichever the line actually needs.

The camera runs a second pass and you see the line clear with your own eyes before we leave.
Same method, same equipment. Only the size of the job changes.




Why us
Amana means trust. Someone else's home is not ours to be careless in.
Do not take our word for it. Look at the line yourself.
Breaking is the last resort, never the first step.
A blocked line does not wait for the morning.
Six governorates, 139 areas.
For buildings and complexes, servicing before the problem starts.
Restaurants, offices and complexes, not only homes.
Common questions
Need someone now? The emergency line is open any hour.
+965 9668 4964
The thermal switch may cut out due to extreme heat spike or unstable voltage. We check both switch and voltage together and replace the switch if cutouts repeat.
If the tank is firmly mounted and cables properly insulated it is safe. But continuous water spray may cause rust over time. We ensure good electrical insulation and ventilation.