Burner inspection
Clean and adjust the burner for even, complete ignition every cycle

Jahra
Repairing gas heaters in Nasseem requires understanding how pipes run through walls and floors and where inlet and outlet connections sit. We inspect the burner, safety components and regulator, testing flow and temperature at each stage.
Modern homes in Nasseem often have heaters mounted on the roof or in a utility room with long supply pipes running from lower floors. We trace the pipe route to check for sharp bends that slow flow or sections exposed to weather. We inspect all pipe joints and test the burner under full pressure so the flame does not go out.
Nasseem is a residential district in Jahra governorate where modern homes have complex heating systems that need regular maintenance.
Before leaving, we heat water to peak temperature and verify flame stability when pressure drops occur.
Clean and adjust the burner for even, complete ignition every cycle
Test every joint with detection solution to locate any minor leak
Inspect the flue path and confirm combustion gases exit the space
Measure thermostat accuracy and test the thermal cut-off safety valve
Check the tank body and the sacrificial anode for corrosion progress
Measure incoming water pressure and confirm it suits the unit's rating
How we work

Tell us what is happening and where, and the right equipment is loaded before we arrive.

We film the line from inside and know the kind of blockage and its exact place. No guessing.

High pressure water, a machine or a drain snake, whichever the line actually needs.

The camera runs a second pass and you see the line clear with your own eyes before we leave.
Same method, same equipment. Only the size of the job changes.




Why us
Amana means trust. Someone else's home is not ours to be careless in.
Do not take our word for it. Look at the line yourself.
Breaking is the last resort, never the first step.
A blocked line does not wait for the morning.
Six governorates, 139 areas.
For buildings and complexes, servicing before the problem starts.
Restaurants, offices and complexes, not only homes.
Common questions
Need someone now? The emergency line is open any hour.
+965 9668 4964
The regulator may not control temperature because of mineral buildup or thermostat failure. We disassemble and clean the regulator or replace it if temperature control is completely lost.
Yes, but proper ventilation and a safe exhaust outlet through copper pipe are essential. We design the new supply and drain route and test everything fully before use.