Burner inspection
Clean and adjust the burner for even, complete ignition every cycle

Capital
Gas heater service in Salhiya includes checking the supply from your cylinder or main inlet, the regulator and nozzles for blockage and damage. We measure outlet temperature, verify heat output and ensure every connection is airtight before handover.
Hotels and large commercial complexes around the Sheraton Hotel in Salhiya use high-capacity gas heaters for heavy hot water demand. We inspect the safety valve, check valve and dip tube for port erosion, and clean the burner head of trapped dirt and grease. If the flame colour shifts from pale blue to yellow the air-gas mix is wrong and the nozzles may need resetting.
Salhiya is a modern commercial district in Kuwait City with high concentration of hotels and offices that depend on reliable gas heaters for daily operations.
We test the safety valve by gradually raising pressure until it opens at 8 bar because over-pressure ruptures the tank.
Clean and adjust the burner for even, complete ignition every cycle
Test every joint with detection solution to locate any minor leak
Inspect the flue path and confirm combustion gases exit the space
Measure thermostat accuracy and test the thermal cut-off safety valve
Check the tank body and the sacrificial anode for corrosion progress
Measure incoming water pressure and confirm it suits the unit's rating
How we work

Tell us what is happening and where, and the right equipment is loaded before we arrive.

We film the line from inside and know the kind of blockage and its exact place. No guessing.

High pressure water, a machine or a drain snake, whichever the line actually needs.

The camera runs a second pass and you see the line clear with your own eyes before we leave.
Same method, same equipment. Only the size of the job changes.




Why us
Amana means trust. Someone else's home is not ours to be careless in.
Do not take our word for it. Look at the line yourself.
Breaking is the last resort, never the first step.
A blocked line does not wait for the morning.
Six governorates, 139 areas.
For buildings and complexes, servicing before the problem starts.
Restaurants, offices and complexes, not only homes.
Common questions
Need someone now? The emergency line is open any hour.
+965 9668 4964
Not necessarily, but it indicates incomplete combustion which may produce carbon monoxide. We check the air mix, clean nozzle ports and restore the safe pale blue flame.
Hotels and offices using the heater daily should have it checked every three months. We verify valves, the exchanger and filter because heavy use speeds wear.