Element condition check
Resistance measured to confirm whether element is scaled, shorted or open

Farwaniya
Thermostat replacement in Ruqai requires careful inspection of the sensor wire and control board. We test the cut-in and cut-off points and fit a standard sensor that holds water in the right range.
Ruqai homes have heaters of varying age, and many have old original thermostats that have failed or stopped responding to temperature. The sensor sits in a metal pocket deep inside the heater near the element, and its wire runs to the external control board. When the sensor fails, water either cools quickly or stays too hot and never cuts off. We disconnect the wire from the board, extract the sensor from its pocket and fit a new one to the same specification.
Ruqai is a residential district in Farwaniya with older family homes where electric heaters often need maintenance.
Before finishing, we set the cut-in point so water temperature does not exceed 65 degrees Celsius during normal operation.
Resistance measured to confirm whether element is scaled, shorted or open
Cutout points tested and temperature calibration verified before fitting new part
Scale deposits inside the tank assessed as they reduce heating efficiency
Anode protects the tank from corrosion and is inspected at every service visit
Wiring and terminals inspected for safety before the new element is energised
Heater run and water temperature confirmed at the tap before the visit ends
How we work

Tell us what is happening and where, and the right equipment is loaded before we arrive.

We film the line from inside and know the kind of blockage and its exact place. No guessing.

High pressure water, a machine or a drain snake, whichever the line actually needs.

The camera runs a second pass and you see the line clear with your own eyes before we leave.
Same method, same equipment. Only the size of the job changes.




Why us
Amana means trust. Someone else's home is not ours to be careless in.
Do not take our word for it. Look at the line yourself.
Breaking is the last resort, never the first step.
A blocked line does not wait for the morning.
Six governorates, 139 areas.
For buildings and complexes, servicing before the problem starts.
Restaurants, offices and complexes, not only homes.
Common questions
Need someone now? The emergency line is open any hour.
+965 9668 4964
If the damage is only in the wire we may be able to reconnect it. But if the sensor itself does not respond to heat, replacement is the only solution.
Water runs without cut-off until it reaches dangerous heat, and the element burns out quickly. The heater must be stopped at once and hot water should not be used until repair is done.