Pipe routing
Mapping every copper run before walls are plastered over

Capital
Central gas in Kaifan runs from the main meter beside Kaifan Co-op to hundreds of flats before plaster goes up. We lay copper through walls and floors from ground up and pressure-test every branch before painting closes the walls.
Large Kaifan towers near Kuwait Sporting Club hold many small and medium flats per building. The challenge is each flat needs its own branch while maintaining steady fall over long vertical runs. We start from the main pipe, run it vertically through distribution columns, then at each floor split short horizontal branches to each unit with individual isolation valves.
Kaifan in Kuwait governorate near Kuwait Sporting Club is a high-density apartment zone where vertical distribution runs complex.
Before each pressure test we remove trapped air from the pipes using a vacuum pump because air pockets distort the readings.
Mapping every copper run before walls are plastered over
Branching the network to each appliance position per plan
Fitting an isolation valve at every outlet for future servicing
Dry nitrogen charge and pressure hold test before handover
Core drilling wall openings and securing pipes with correct clips
Recording final pipe routes for future maintenance reference
How we work

Tell us what is happening and where, and the right equipment is loaded before we arrive.

We film the line from inside and know the kind of blockage and its exact place. No guessing.

High pressure water, a machine or a drain snake, whichever the line actually needs.

The camera runs a second pass and you see the line clear with your own eyes before we leave.
Same method, same equipment. Only the size of the job changes.




Why us
Amana means trust. Someone else's home is not ours to be careless in.
Do not take our word for it. Look at the line yourself.
Breaking is the last resort, never the first step.
A blocked line does not wait for the morning.
Six governorates, 139 areas.
For buildings and complexes, servicing before the problem starts.
Restaurants, offices and complexes, not only homes.
Common questions
Need someone now? The emergency line is open any hour.
+965 9668 4964
We use a larger main distribution column running vertically, then from each point branch thinner horizontal pipes to the flats. Every horizontal branch has a steady fall from the column to the kitchen outlet.
No, because each flat has its own isolation valve. We close the leaking unit's valve and retest, then cut the wall at the leak point and repair the pipe inside the wall.