Central gas first-fix
Main gas network laid and pressure-tested before walls are plastered.

Farwaniya
Central gas line installation in Khitan Al-Jadida starts by mapping pipe runs from the distribution meter through every room in the home. We test each joint under high pressure before appliances are connected. Final inspection confirms no gas escape anywhere in the property.
Most Khitan Al-Jadida houses are modern multi-storey buildings where kitchens, bathrooms and rooms are close together, meaning gas lines can run as short straight copper pipe. We mount the main regulator beside the meter and run individual branches to the cooker, heater and heating unit. Foam testing reveals any leak point at once.
Khitan Al-Jadida is in Farwaniya governorate, a modern residential district where central gas connection is usually a standard requirement at handover.
Each line is pressurised at 0.5 bar for ten minutes to measure any drop before the first appliance is opened.
Main gas network laid and pressure-tested before walls are plastered.
Residential kitchen gas points run to correct sizing and outlet count.
Commercial kitchen gas networks sized for high demand with isolation at each appliance.
Leak located with detection instruments before any wall or floor is opened.
Ball valves fitted at the main inlet and at every branch point.
Periodic check of all valves, joints and fittings across the gas network.
How we work

Tell us what is happening and where, and the right equipment is loaded before we arrive.

We film the line from inside and know the kind of blockage and its exact place. No guessing.

High pressure water, a machine or a drain snake, whichever the line actually needs.

The camera runs a second pass and you see the line clear with your own eyes before we leave.
Same method, same equipment. Only the size of the job changes.




Why us
Amana means trust. Someone else's home is not ours to be careless in.
Do not take our word for it. Look at the line yourself.
Breaking is the last resort, never the first step.
A blocked line does not wait for the morning.
Six governorates, 139 areas.
For buildings and complexes, servicing before the problem starts.
Restaurants, offices and complexes, not only homes.
Common questions
Need someone now? The emergency line is open any hour.
+965 9668 4964
No, exposed copper pipe is adequately protected if bracketed every 60 centimetres with metal clips and kept clear of hot surfaces. Burying pipes in walls adds complexity and no real safety gain.
We bend the copper pipe in a gentle curve around the wall or run it beneath floor tiles if the fall allows it. Load-bearing walls are never drilled through.