Copper or steel pipe run
Correct diameter pipe sized to kitchen appliance load and inlet pressure.

Capital
A kitchen gas line in Dasma runs from the inlet point at the meter to each cooking appliance. We lay copper pipe in the right diameters, secure it with metal clips and test pressure and leaks before handover.
Dasma older houses often have kitchens far from the inlet, so the gas line must travel a long way through hallways and interior walls. We trace the pipe route first to check for buried electrical cables and nails, then secure it with metal clips every metre and a half. Where the line emerges from the wall, a short flexible connector joins the fixed pipe to the appliance outlet.
Dasma lies in Kuwait governorate near the city centre, a long-established residential area of family houses with kitchens of varying layouts.
Before handover, every joint is checked with soapy water under normal network pressure to confirm there are no leaks.
Correct diameter pipe sized to kitchen appliance load and inlet pressure.
Individual outlet with isolation valve for each hob, oven or fryer.
Pipe run inside protective conduit or channel with ventilation clearance observed.
Joints finished by brazing or press-fit method suited to the pipe material.
Nitrogen pumped to test pressure and held to confirm every joint is tight.
Inspection of an existing run and repair of any corroded section or weeping joint.
How we work

Tell us what is happening and where, and the right equipment is loaded before we arrive.

We film the line from inside and know the kind of blockage and its exact place. No guessing.

High pressure water, a machine or a drain snake, whichever the line actually needs.

The camera runs a second pass and you see the line clear with your own eyes before we leave.
Same method, same equipment. Only the size of the job changes.




Why us
Amana means trust. Someone else's home is not ours to be careless in.
Do not take our word for it. Look at the line yourself.
Breaking is the last resort, never the first step.
A blocked line does not wait for the morning.
Six governorates, 139 areas.
For buildings and complexes, servicing before the problem starts.
Restaurants, offices and complexes, not only homes.
Common questions
Need someone now? The emergency line is open any hour.
+965 9668 4964
Copper pipes are always fixed to walls or ceilings because embedding them in floors makes testing and maintenance impossible. Wall mounting lets us see every joint and check for leaks whenever needed.
It depends on the pipe diameter, the number of burners on each appliance and the distance from the meter. We calculate the load and select a diameter that handles all appliances running together without pressure drop.
