Copper or steel pipe run
Correct diameter pipe sized to kitchen appliance load and inlet pressure.

Capital
A kitchen gas line in Rawda starts at the external meter and reaches each cooking appliance with precision and strict testing. We run the line under full pressure for diagnosis. Every joint is checked with an electronic detector. The family gets a test certificate at handover.
Rawda villas around Rawda Park have spacious kitchens with deep shelving and overhead cabinets. The gas line must pass under these cabinets without touching any metal part. We measure distances carefully before laying pipes and use isolation pads to separate pipe from metal frame. Many villas here have an island cooker in the centre requiring a gas line suspended overhead to avoid direct heat.
Rawda lies in Kuwait governorate near Rawda Park, a leafy villa area where kitchens are spacious and gas lines need heat protection.
We test the overhead pipe section for any plastic component damage from heat released by appliances mounted above.
Correct diameter pipe sized to kitchen appliance load and inlet pressure.
Individual outlet with isolation valve for each hob, oven or fryer.
Pipe run inside protective conduit or channel with ventilation clearance observed.
Joints finished by brazing or press-fit method suited to the pipe material.
Nitrogen pumped to test pressure and held to confirm every joint is tight.
Inspection of an existing run and repair of any corroded section or weeping joint.
How we work

Tell us what is happening and where, and the right equipment is loaded before we arrive.

We film the line from inside and know the kind of blockage and its exact place. No guessing.

High pressure water, a machine or a drain snake, whichever the line actually needs.

The camera runs a second pass and you see the line clear with your own eyes before we leave.
Same method, same equipment. Only the size of the job changes.




Why us
Amana means trust. Someone else's home is not ours to be careless in.
Do not take our word for it. Look at the line yourself.
Breaking is the last resort, never the first step.
A blocked line does not wait for the morning.
Six governorates, 139 areas.
For buildings and complexes, servicing before the problem starts.
Restaurants, offices and complexes, not only homes.
Common questions
Need someone now? The emergency line is open any hour.
+965 9668 4964
Yes if the pipe is the right diameter and wrapped in heat-resistant insulation. We raise it high enough above the heat source and test it under full load.
We use solid plastic pads to separate the pipe from metal completely. This blocks heat conduction and protects the pipe from stray hot and cold spots.