Main pipe run
Running the supply line into the kitchen at the correct pipe diameter

Capital
Restaurant gas lines in Sharq, around Sharq Marina and the office towers near the NBK Head Office, usually serve enclosed kitchens with mechanical extraction. We interlock the gas supply with the hood fan, so gas only flows while the extract system is running.
Kitchens in the food courts and restaurants between Kuwait Towers and Sharq Marina often have no opening windows, so combustion fumes rely entirely on the hood. If the fan trips and cooks keep going, carbon monoxide builds up quickly. We fit a solenoid valve on the kitchen branch, wire it through an airflow or current sensor on the extract fan, add a clearly marked reset, and test the interlock by switching the fan off with burners lit.
Sharq is the capital's waterfront business district between Kuwait Towers and Sharq Marina, with many enclosed restaurant kitchens.
The gas and hood interlock is tested at handover by stopping the fan with the burners lit.
Running the supply line into the kitchen at the correct pipe diameter
Dedicated branch for each burner, oven, grill or fryer in the kitchen
Valve at each appliance so one unit can be isolated without stopping the whole line
Pipes run inside the wall or surface-mounted to suit the building structure
Completed network tested under dry nitrogen pressure before any appliance is connected
Inspecting or extending a working kitchen gas network with minimal downtime
How we work

Tell us what is happening and where, and the right equipment is loaded before we arrive.

We film the line from inside and know the kind of blockage and its exact place. No guessing.

High pressure water, a machine or a drain snake, whichever the line actually needs.

The camera runs a second pass and you see the line clear with your own eyes before we leave.
Same method, same equipment. Only the size of the job changes.




Why us
Amana means trust. Someone else's home is not ours to be careless in.
Do not take our word for it. Look at the line yourself.
Breaking is the last resort, never the first step.
A blocked line does not wait for the morning.
Six governorates, 139 areas.
For buildings and complexes, servicing before the problem starts.
Restaurants, offices and complexes, not only homes.
Common questions
Need someone now? The emergency line is open any hour.
+965 9668 4964
Yes, if the fan is switched off for cleaning, the interlock closes the gas as designed. Clean filters when burners are off, then restart the fan before relighting.
In most kitchens, yes. It needs a solenoid on the gas branch and a sensor on the fan, both of which can be fitted with a short gas shutdown.