Cold water supply
PPR runs to every tap, cistern and appliance point in the unit

Hawalli
Apartment pipe runs in Anjafa begin with framing survey and main riser positioning based on unit layouts. We extend supply and waste lines ensuring correct fall and full insulation before closure. Every line is high-pressure tested and documented before the project moves to following phases.
Residential apartments in Anjafa range from studio units to large family flats in mixed-use towers. Main risers are usually placed in perimeter walls or intermediate chases for easier access and maintenance. Horizontal waste from each unit falls at a consistent gradient to the central stack, reducing under-slab pipe complexity.
Anjafa lies in Hawalli governorate, a mixed residential district with diverse development of apartments and shops.
Plastic pipes are fixed with metal clips at 60 cm intervals to prevent sagging during testing.
PPR runs to every tap, cistern and appliance point in the unit
uPVC drain lines graded to prevent standing water and blockages
Waste and supply stubs positioned accurately before screed is poured
Supply and waste points for sink, washing machine and refrigerator
Recorded pressure test on the supply network before walls are closed
Connecting the unit's supply line to the building tank and pump system
How we work

Tell us what is happening and where, and the right equipment is loaded before we arrive.

We film the line from inside and know the kind of blockage and its exact place. No guessing.

High pressure water, a machine or a drain snake, whichever the line actually needs.

The camera runs a second pass and you see the line clear with your own eyes before we leave.
Same method, same equipment. Only the size of the job changes.




Why us
Amana means trust. Someone else's home is not ours to be careless in.
Do not take our word for it. Look at the line yourself.
Breaking is the last resort, never the first step.
A blocked line does not wait for the morning.
Six governorates, 139 areas.
For buildings and complexes, servicing before the problem starts.
Restaurants, offices and complexes, not only homes.
Common questions
Need someone now? The emergency line is open any hour.
+965 9668 4964
Yes, a studio with one bathroom may need only 20 mm waste instead of 32 mm. But fall must remain consistent and pressure testing remains mandatory at the same level.
We use flexible clips and short risers between pipes and structure to absorb building movement. Vertical pipes are left with a small expansion margin in chases before closure.