Cold water supply
PPR runs to every tap, cistern and appliance point in the unit

Hawalli
Apartment pipe runs in Siddiq face the challenge of high residential density where towers stand very close together. We design strong main risers with multi-level distribution and test each section under full pressure before closure. Coordination with the contractor on work sequencing is essential to avoid routing conflicts.
Apartments in the dense Siddiq district typically have standardized layouts with a main bathroom, guest bathroom and standard load-bearing walls. Main risers pass through very tight central chases requiring precisely calculated pipe diameters. Grey water from kitchen and bathrooms falls to one main stack while a separate black water stack is used where codes require it.
Siddiq lies in Hawalli governorate, a dense residential district with rapid urban development and closely packed apartment clusters.
The main waste stack is tested by filling from the top floor to monitor flow speed and air entrainment.
PPR runs to every tap, cistern and appliance point in the unit
uPVC drain lines graded to prevent standing water and blockages
Waste and supply stubs positioned accurately before screed is poured
Supply and waste points for sink, washing machine and refrigerator
Recorded pressure test on the supply network before walls are closed
Connecting the unit's supply line to the building tank and pump system
How we work

Tell us what is happening and where, and the right equipment is loaded before we arrive.

We film the line from inside and know the kind of blockage and its exact place. No guessing.

High pressure water, a machine or a drain snake, whichever the line actually needs.

The camera runs a second pass and you see the line clear with your own eyes before we leave.
Same method, same equipment. Only the size of the job changes.




Why us
Amana means trust. Someone else's home is not ours to be careless in.
Do not take our word for it. Look at the line yourself.
Breaking is the last resort, never the first step.
A blocked line does not wait for the morning.
Six governorates, 139 areas.
For buildings and complexes, servicing before the problem starts.
Restaurants, offices and complexes, not only homes.
Common questions
Need someone now? The emergency line is open any hour.
+965 9668 4964
We use 50 mm for cold distribution and 32 mm for waste where the chase allows. If the chase is tighter we raise the outlet higher or use wall distribution instead of central.
Yes, but it requires a separate branch run from the entire floor to the main stack. This increases wall and slab penetrations so we only recommend it if the owner or code requires it.