Hot and cold supply points
PPR lines routed precisely to basin, shower and toilet positions

Capital
Bathroom rough-in in Kaifan demands careful planning because most villas need multiple bathrooms with high flow demands. We run supply pipes from roof heaters and ground tanks and set multiple traps before walls close. Every outlet is tested for pressure and flow. This ensures taps do not starve each other.
Kaifan villas near Kuwait Sporting Club spread across wide footprints with three or more bathrooms across men's, women's and guest wings. Pipes run from a central roof tank on one side of the building to each bathroom, with insulated hot branches. We calculate heat loss over distance and apply thick foam wrap. Waste splits between at least three main stacks to prevent choking during simultaneous use.
Kaifan is an upscale villa area in Kuwait City near Kuwait Sporting Club, where spacious multi-wing buildings dominate.
We test three bathrooms together under full pressure because simultaneous use is the norm in large villas.
PPR lines routed precisely to basin, shower and toilet positions
uPVC drain runs laid at correct fall to prevent standing water
Floor trap levels set before screed to align flush with final tiling
Connecting the waste run to the vent stack prevents trap siphoning and odour
Documented pressure test on supply lines before walls are permanently closed
All supply and waste point locations recorded for finishing and future maintenance
How we work

Tell us what is happening and where, and the right equipment is loaded before we arrive.

We film the line from inside and know the kind of blockage and its exact place. No guessing.

High pressure water, a machine or a drain snake, whichever the line actually needs.

The camera runs a second pass and you see the line clear with your own eyes before we leave.
Same method, same equipment. Only the size of the job changes.




Why us
Amana means trust. Someone else's home is not ours to be careless in.
Do not take our word for it. Look at the line yourself.
Breaking is the last resort, never the first step.
A blocked line does not wait for the morning.
Six governorates, 139 areas.
For buildings and complexes, servicing before the problem starts.
Restaurants, offices and complexes, not only homes.
Common questions
Need someone now? The emergency line is open any hour.
+965 9668 4964
There is no single answer. If bathrooms cluster together, one thick 100mm stack suffices. If they spread, we use two or three stacks to distribute load and prevent backflow. We measure distances and expected use before deciding.
Yes, if the heater is sized right and supply pipes are well-insulated. We add thick foam wrap on each hot branch to cut heat loss. Before finishing we check water temperature at the farthest bathroom to ensure warm water arrives, not cold.