Horizontal drain runs
uPVC pipes graded to correct fall for each wet room and kitchen

Ahmadi
Drain-line installation in Maqwa deals with hard rocky soil and high groundwater. We dig deep trenches carefully, install pressure-rated pipes, and test everything under high water pressure before backfill.
Maqwa is an industrial area near KOC oil fields where soil is very rocky and groundwater sits close to the surface. We use heavy excavation equipment and bed pipes on sand to prevent fractures from sharp stones. We install larger-diameter floor traps because groundwater pressure may affect drainage, and we test all joints under at least 2 bar pressure to prevent groundwater seeping into the pipes.
Maqwa sits in Ahmadi governorate near oil fields, an industrial area with rocky ground.
Every drain line is pressure-tested at 2 bar for at least one hour before backfill, because groundwater in Maqwa exerts external pressure on the pipes.
uPVC pipes graded to correct fall for each wet room and kitchen
vent column fitted to prevent trap siphoning and sewer odour indoors
cleanout positions fixed before burial so future maintenance needs no breaking
floor traps set at correct level before screed is poured over them
building drain lines connected to the external sewer at correct invert level
all drain lines water-tested before burial to confirm joints are sound
How we work

Tell us what is happening and where, and the right equipment is loaded before we arrive.

We film the line from inside and know the kind of blockage and its exact place. No guessing.

High pressure water, a machine or a drain snake, whichever the line actually needs.

The camera runs a second pass and you see the line clear with your own eyes before we leave.
Same method, same equipment. Only the size of the job changes.




Why us
Amana means trust. Someone else's home is not ours to be careless in.
Do not take our word for it. Look at the line yourself.
Breaking is the last resort, never the first step.
A blocked line does not wait for the morning.
Six governorates, 139 areas.
For buildings and complexes, servicing before the problem starts.
Restaurants, offices and complexes, not only homes.
Common questions
Need someone now? The emergency line is open any hour.
+965 9668 4964
Because groundwater in Maqwa sits very close to the surface and surrounds pipes from outside. If there is even a small gap in any joint, groundwater will seep in and clog the drain line.
We use PVC or concrete pipes with thicker walls to withstand external pressure from groundwater. The diameter is also usually at least 50 mm larger than in other areas.