Pressure diagnosis
Pressure measured at multiple points to pinpoint exactly where the fault lies

Ahmadi
Diagnosing low water pressure in Bnaidar starts by checking the supply method, whether a roof tank or a borehole pump delivers directly. We inspect the main feed line, the control valve and the filter, then test pressure at every outlet. We disconnect joints, flush pipes under pressure and clean tap aerators before retesting.
Many Bnaidar desert houses rely on private boreholes with submersible pumps buried underground, and these pumps fill the roof tank or feed the indoor network directly. If a pump is old or a large AC unit fails, pressure drops noticeably. We test the pump by reading outlet pressure and inspecting intake and discharge valves, and we also measure water flow over one minute.
Bnaidar lies in the Ahmadi desert, a remote area relying on boreholes and independent pump systems separate from the public network.
We measure pump discharge pressure at the borehole head before the line enters the house.
Pressure measured at multiple points to pinpoint exactly where the fault lies
Transfer pump, pressure switch and expansion vessel checked and set correctly
Mineral scale cleared from pipes, pressure reducers and aerators blocking flow
Pressure-reducing valve inspected, adjusted or replaced if it restricts supply
Tank level, float valve and inlet pipe verified to rule out supply shortfall
Pressure confirmed at all outlets after repair before the visit closes
How we work

Tell us what is happening and where, and the right equipment is loaded before we arrive.

We film the line from inside and know the kind of blockage and its exact place. No guessing.

High pressure water, a machine or a drain snake, whichever the line actually needs.

The camera runs a second pass and you see the line clear with your own eyes before we leave.
Same method, same equipment. Only the size of the job changes.




Why us
Amana means trust. Someone else's home is not ours to be careless in.
Do not take our word for it. Look at the line yourself.
Breaking is the last resort, never the first step.
A blocked line does not wait for the morning.
Six governorates, 139 areas.
For buildings and complexes, servicing before the problem starts.
Restaurants, offices and complexes, not only homes.
Common questions
Need someone now? The emergency line is open any hour.
+965 9668 4964
Yes, large AC units draw heavy current, and if the borehole pump is small it cannot compete. We test the electrical voltage to the pump and consider adding a secondary roof tank or upgrading the pump itself.
At least yearly or more if groundwater is sandy. We disassemble the filter, wash it with clean water and consider fitting a larger screen if blockage keeps happening.