Drain and supply check
Outlet position and height confirmed before the unit is placed

Farwaniya
Bathtub installation in older Farwaniya blocks, near Farwaniya Hospital and the Third Ring Road, has to deal with one recurring issue: sewer smell from the trap. We fit a deep-seal trap and a properly joined overflow from the start, so the new bath keeps the room fresh.
A bath is used less often than a basin, so its trap water can evaporate in the heat and open a path for drain air. We fit a deep-seal trap that holds more water, connect the overflow tube with a sealed joint rather than a push fit, and check the branch for an air admittance valve where venting is poor. In Farwaniya buildings where the stack is shared by many flats, that last step matters most.
Farwaniya is the hub of Farwaniya governorate, around Farwaniya Hospital, Farwaniya Co-op and the Third Ring Road.
Tubs we fit in Farwaniya use a deep-seal trap and a sealed overflow joint instead of a push fit.
Outlet position and height confirmed before the unit is placed
Bath feet adjusted until all four sides read level
Waste and overflow set fitted with a proper sealed gasket
Hot and cold lines connected with isolation valves and braided hoses
Non-fungal sanitary silicone along the full bath-to-tile joint
Unit filled and drained to verify every joint before handover
How we work

Tell us what is happening and where, and the right equipment is loaded before we arrive.

We film the line from inside and know the kind of blockage and its exact place. No guessing.

High pressure water, a machine or a drain snake, whichever the line actually needs.

The camera runs a second pass and you see the line clear with your own eyes before we leave.
Same method, same equipment. Only the size of the job changes.




Why us
Amana means trust. Someone else's home is not ours to be careless in.
Do not take our word for it. Look at the line yourself.
Breaking is the last resort, never the first step.
A blocked line does not wait for the morning.
Six governorates, 139 areas.
For buildings and complexes, servicing before the problem starts.
Restaurants, offices and complexes, not only homes.
Common questions
Need someone now? The emergency line is open any hour.
+965 9668 4964
The trap water has probably dried out. Running the tap briefly refills it, and a deep-seal trap slows evaporation.
A one-way valve that lets air into the drain when water flows, so the trap is not sucked dry. It helps where the building vent is weak.