Concealed frame fitting
Steel carrier frame anchored at the specified height inside the wall

Farwaniya
Wall-hung toilet installation in Abraq Khitan requires checking modern residential house walls and finding the right drainage route. We run lines with precise fall, bolt the frame solid, fit all parts, and pressure-test fully.
Abraq Khitan houses are relatively new with insulated concrete walls and modern drainage pipes with easy-access inspection points. Main pipes are laid regularly under the floor with steady falls, making new frame addition straightforward. We measure height and distance from drainage, then position the frame to align with existing pipes. Fixing is simple because concrete is solid and bolts go in easily.
Abraq Khitan is in Farwaniya governorate, a modern residential area with organised and uniform drainage pipes.
All bolts are hand-tested for tightness before frame installation to confirm they have driven deep into concrete.
Steel carrier frame anchored at the specified height inside the wall
Waste pipe set at the correct fall to prevent backflow and odour
Supply line connected with an accessible isolation valve behind the service panel
Flush volume and fill valve pressure adjusted to stop continuous water loss
Bowl hung on frame studs with correct bolts and seat fitted firmly
Full leak check before wall is closed and again after cladding is in place
How we work

Tell us what is happening and where, and the right equipment is loaded before we arrive.

We film the line from inside and know the kind of blockage and its exact place. No guessing.

High pressure water, a machine or a drain snake, whichever the line actually needs.

The camera runs a second pass and you see the line clear with your own eyes before we leave.
Same method, same equipment. Only the size of the job changes.




Why us
Amana means trust. Someone else's home is not ours to be careless in.
Do not take our word for it. Look at the line yourself.
Breaking is the last resort, never the first step.
A blocked line does not wait for the morning.
Six governorates, 139 areas.
For buildings and complexes, servicing before the problem starts.
Restaurants, offices and complexes, not only homes.
Common questions
Need someone now? The emergency line is open any hour.
+965 9668 4964
Yes if the new wall is near existing drainage pipes. We check distance and fall first. If it is too far away, we need a longer new waste pipe under the floor.
The frame and lines are tested at 4 bar pressure for at least 10 minutes. This pressure confirms all joints and bolts are sound. Any small leak will show at this stage.