Concealed frame fitting
Steel carrier frame anchored at the specified height inside the wall

Farwaniya
A wall-hung toilet installation in Rehab starts with a strong steel frame anchored behind the tiles before any finishing. We run supply and waste lines inside the wall, mount the pan and cistern, then test pressure after final connection.
Most Rehab homes have narrow ground-floor bathrooms, and a wall-hung pan takes up less floor space than a traditional pedestal. We start by checking wall thickness and existing pipe runs, because the frame needs a solid central hole that lines up with the main waste. If the wall is thin or the soil pipe is distant, we propose a short angled bridge instead of bends that trap solids.
Rehab lies in Farwaniya governorate, a suburban family district where small bathrooms need space-saving solutions.
We test supply and waste joints under full pressure for two minutes before covering the frame because later access means removing tiles.
Steel carrier frame anchored at the specified height inside the wall
Waste pipe set at the correct fall to prevent backflow and odour
Supply line connected with an accessible isolation valve behind the service panel
Flush volume and fill valve pressure adjusted to stop continuous water loss
Bowl hung on frame studs with correct bolts and seat fitted firmly
Full leak check before wall is closed and again after cladding is in place
How we work

Tell us what is happening and where, and the right equipment is loaded before we arrive.

We film the line from inside and know the kind of blockage and its exact place. No guessing.

High pressure water, a machine or a drain snake, whichever the line actually needs.

The camera runs a second pass and you see the line clear with your own eyes before we leave.
Same method, same equipment. Only the size of the job changes.




Why us
Amana means trust. Someone else's home is not ours to be careless in.
Do not take our word for it. Look at the line yourself.
Breaking is the last resort, never the first step.
A blocked line does not wait for the morning.
Six governorates, 139 areas.
For buildings and complexes, servicing before the problem starts.
Restaurants, offices and complexes, not only homes.
Common questions
Need someone now? The emergency line is open any hour.
+965 9668 4964
Standard frames sit fifteen centimetres deep and need walls at least ten centimetres thick. If thinner, we use a shallow frame with half the depth but less rigidity under load.
Yes, if the existing pipe runs directly behind the wall where we anchor the frame. We measure the distance, connect with a short horizontal metal bend, then raise it into the soil pipe at a steady fall.