Current pump assessment
Checking amperage, pressure and mechanical condition before any decision

Ahmadi
Cesspit pump installation in Ruqqa begins by assessing drainage from residential buildings and checking the underground tank capacity. We select a pump horsepower suited to tank depth and discharge pipe length. We connect power and over-current protection, then run the system at full load to confirm performance.
Old Ruqqa apartment buildings share cesspits under the central courtyard, with pipes from each flat joining a single very deep tank. We measure building height and total lift distance because the pump must raise foul water several storeys. We inspect old tank walls and heavy sediment on the bottom before selecting a pump rated for solids handling.
Ruqqa is an established residential district in Ahmadi governorate where multi-storey apartment blocks each rely on their own private drainage system.
We test the pump under full load while monitoring suction pressure to ensure no air leaks from joints.
Checking amperage, pressure and mechanical condition before any decision
Sizing by pit volume, depth and discharge pipe diameter
Discharge line fitted with a non-return valve and sealed joints
Moisture-rated connection suited to a submerged cesspit environment
Float set to correct on and off levels to prevent dry running
Pit filled and a full pump cycle run before the technician leaves
How we work

Tell us what is happening and where, and the right equipment is loaded before we arrive.

We film the line from inside and know the kind of blockage and its exact place. No guessing.

High pressure water, a machine or a drain snake, whichever the line actually needs.

The camera runs a second pass and you see the line clear with your own eyes before we leave.
Same method, same equipment. Only the size of the job changes.




Why us
Amana means trust. Someone else's home is not ours to be careless in.
Do not take our word for it. Look at the line yourself.
Breaking is the last resort, never the first step.
A blocked line does not wait for the morning.
Six governorates, 139 areas.
For buildings and complexes, servicing before the problem starts.
Restaurants, offices and complexes, not only homes.
Common questions
Need someone now? The emergency line is open any hour.
+965 9668 4964
We select a larger pump with reinforced impellers rated for solids and grease buildup. We install a strainer at the cesspit inlet to catch large debris. Regular maintenance clears sediment from the tank.
Yes, we install a dual-pump manifold with check valves allowing two pumps to run in parallel or one as standby. The first pump runs normally and the second starts automatically if the first fails. Both pumps are tested before handover.