Roof-tank pump
Transfers water from ground tank to roof tank reliably.

Hawalli
Water pump installation in Jabriya starts with a thorough check of the supply line from the street meter to the roof tank in the residential villa. We check incoming water pressure and expected load, then select a pump of appropriate power with a separate suction line from the underground tank. We clean the main pipes of debris before connection and run the full system to verify performance.
Jabriya villas have large roof tanks and modern pipe systems, and the pump lifts water from a deep underground tank to the roof at heights up to eight metres. We measure pressure at the suction point and the highest point in the roof tank, ensuring the supply pipe slope supports one-way flow. Where the villa has a central hot-water system, we may fit a small second pump to ensure steady circulation of hot water through distribution pipes.
Jabriya in Hawalli governorate, near Mubarak Hospital and American University of Kuwait, is an upscale residential area of spacious villas.
The pump pressure reading is recorded on a data plate mounted beside it as reference for any future maintenance.
Transfers water from ground tank to roof tank reliably.
Keeps hot water at the tap without a long wait.
Sets correct cut-in and cut-out points, stops short-cycling.
Evacuates cesspits efficiently with a non-return valve fitted.
Lifts sewage from low-level units to the drainage network.
Protects basements from water accumulation via float-activated switch.
How we work

Tell us what is happening and where, and the right equipment is loaded before we arrive.

We film the line from inside and know the kind of blockage and its exact place. No guessing.

High pressure water, a machine or a drain snake, whichever the line actually needs.

The camera runs a second pass and you see the line clear with your own eyes before we leave.
Same method, same equipment. Only the size of the job changes.




Why us
Amana means trust. Someone else's home is not ours to be careless in.
Do not take our word for it. Look at the line yourself.
Breaking is the last resort, never the first step.
A blocked line does not wait for the morning.
Six governorates, 139 areas.
For buildings and complexes, servicing before the problem starts.
Restaurants, offices and complexes, not only homes.
Common questions
Need someone now? The emergency line is open any hour.
+965 9668 4964
Yes if we select the pump based on tank size and required pressure. We calculate tank volume divided by desired fill time, then choose a pump with flow matching that load. For very large tanks, we might suggest two smaller pumps instead of one large one.
Often the cause is a small leak in one of the new connections or air entering the suction line. We check all joints for water drips and verify the suction valve closes properly when the pump stops.