Roof tank installation
Polyethylene tank set on roof with supply, overflow and pump lines connected

Hawalli
Water tanks in Jabriya are fitted to spacious villa roofs and residential buildings near the American University. We size the tank by occupant count and daily consumption. We run supply and draw-off pipes, fit the float valve and pump and test everything.
Jabriya is a spacious family district with villas and gardens and modern residential buildings. Near Mubarak Hospital tanks are usually larger because villas here are deep and may need multiple lift pumps. We check roof height above the highest consumption point and calculate whether natural pressure is enough or a second pump is needed, and regulate pressure valves to ensure steady pressure on all floors.
Jabriya in Hawalli governorate is an upscale residential district where most villas and buildings have roof tanks.
Tank and pump are tested together at maximum pressure and pressure stability is checked at all consumption points.
Polyethylene tank set on roof with supply, overflow and pump lines connected
Watertight underground tank built with access hatches and rising main connected
Mains supply connected to tank with float valve and isolation fitted
Overflow routed away from the building at correct fall to prevent backflow
Transfer or pressure pump connected to tank and tested under load
Full network pressure test after installation confirms every joint holds
How we work

Tell us what is happening and where, and the right equipment is loaded before we arrive.

We film the line from inside and know the kind of blockage and its exact place. No guessing.

High pressure water, a machine or a drain snake, whichever the line actually needs.

The camera runs a second pass and you see the line clear with your own eyes before we leave.
Same method, same equipment. Only the size of the job changes.




Why us
Amana means trust. Someone else's home is not ours to be careless in.
Do not take our word for it. Look at the line yourself.
Breaking is the last resort, never the first step.
A blocked line does not wait for the morning.
Six governorates, 139 areas.
For buildings and complexes, servicing before the problem starts.
Restaurants, offices and complexes, not only homes.
Common questions
Need someone now? The emergency line is open any hour.
+965 9668 4964
Usually yes. A single pump may not deliver enough pressure to upper floors if the villa is very deep. We fit a first lift pump from the underground tank and an intermediate booster on the first floor to reinforce upper pressure.
We fit a pressure regulator on the main distribution line and test it at every consumption point before handover. Pressure must be 2 to 4 bar at all taps and outlets.