Roof-tank pump
Transfers water from ground tank to roof tank reliably.

Mubarak Al-Kabeer
Summer power fluctuations are hard on pumps, and water pump installation and service in Mubarak Al-Kabeer includes protecting them. On villas near Mubarak Al-Kabeer Co-op, we fit relays that cut the motor on low voltage or a lost phase, then restart it safely when supply steadies.
Larger villas in the Mubarak Al-Kabeer suburb, a short drive from Messila Beach, often run three phase booster and transfer pumps. If one phase drops during a summer peak, the motor keeps trying to turn on two phases and overheats within minutes. We add a phase and voltage monitoring relay to the starter, set a restart delay so pumps do not all start together when power returns, and check the motor's insulation and current draw.
Mubarak Al-Kabeer is a residential suburb near Messila Beach, where larger villas often run three phase water pumps.
Three phase pumps get a phase and voltage relay, so a lost phase stops the motor before it overheats.
Transfers water from ground tank to roof tank reliably.
Keeps hot water at the tap without a long wait.
Sets correct cut-in and cut-out points, stops short-cycling.
Evacuates cesspits efficiently with a non-return valve fitted.
Lifts sewage from low-level units to the drainage network.
Protects basements from water accumulation via float-activated switch.
How we work

Tell us what is happening and where, and the right equipment is loaded before we arrive.

We film the line from inside and know the kind of blockage and its exact place. No guessing.

High pressure water, a machine or a drain snake, whichever the line actually needs.

The camera runs a second pass and you see the line clear with your own eyes before we leave.
Same method, same equipment. Only the size of the job changes.




Why us
Amana means trust. Someone else's home is not ours to be careless in.
Do not take our word for it. Look at the line yourself.
Breaking is the last resort, never the first step.
A blocked line does not wait for the morning.
Six governorates, 139 areas.
For buildings and complexes, servicing before the problem starts.
Restaurants, offices and complexes, not only homes.
Common questions
Need someone now? The emergency line is open any hour.
+965 9668 4964
Often yes. A lost phase or low voltage before or after an outage is a common cause, and a monitoring relay would have stopped the motor in time.
Single phase pumps can still suffer from low voltage. A simple voltage protector on the supply is worthwhile for them as well.