Live pressure reading
Measuring cut-in and cut-out values before touching anything

Mubarak Al-Kabeer
Repairing the pressure switch in Funaitees ensures the roof tank fills at steady pressure without frequent pump stops. We read current pressure on the gauge, inspect the tank membrane and adjust cut and reconnect points. Final testing confirms no air leaks and the switch responds quickly.
Funaitees houses are close-built and most roof tanks are relatively small, meaning the switch must be sensitive to prevent wide gaps between pump start and stop. A small tank fills quickly, so if cut-out is set too high the pump starts, stops and starts without settling. We test switch response at actual well flow and adjust the gap between points so it is at least half bar.
Funaitees sits near Mubarak Al-Kabeer governorate and holds dense residential houses with varied pressure tanks.
We test the air charge by isolating water from the tank to measure initial air pressure accurately.
Measuring cut-in and cut-out values before touching anything
Testing the air bladder charge and refilling it if pressure is lost
Cleaning contacts or fitting a new switch matched to pump capacity
Calibrating both thresholds precisely to prevent rapid on-off cycling
Inspecting wiring and terminal resistance at both switch contacts
Running the pump and confirming stable pressure through a full cycle
How we work

Tell us what is happening and where, and the right equipment is loaded before we arrive.

We film the line from inside and know the kind of blockage and its exact place. No guessing.

High pressure water, a machine or a drain snake, whichever the line actually needs.

The camera runs a second pass and you see the line clear with your own eyes before we leave.
Same method, same equipment. Only the size of the job changes.




Why us
Amana means trust. Someone else's home is not ours to be careless in.
Do not take our word for it. Look at the line yourself.
Breaking is the last resort, never the first step.
A blocked line does not wait for the morning.
Six governorates, 139 areas.
For buildings and complexes, servicing before the problem starts.
Restaurants, offices and complexes, not only homes.
Common questions
Need someone now? The emergency line is open any hour.
+965 9668 4964
Usually the gap between cut-in and cut-out is too wide, so the pump jumps between low and high pressure. We narrow the gap so the transition is smooth, which reduces noise and vibration.
Yes, small tanks need a narrow gap between points to avoid frequent cycling. Large tanks allow a wider gap because they fill and empty more slowly.
