Tank and line check
Tank size and pipe run checked before any pump is chosen

Capital
Roof tank pumping in Shuwaikh Industrial requires a powerful pump because warehouses and factories draw heavy water use throughout the day. We mount the pump on a concrete pad and run larger-diameter lines across longer distances.
Warehouses and factories in Shuwaikh Industrial have tall roofs and large tanks holding ten tonnes or more to meet heavy demand. Water lines run across long spans over multiple floors and separate sections, meaning pressure drops sharply with an undersized pump. We fit the main line in 50 or 63 millimetre diameter and anchor supports at intervals to prevent pipe vibration.
Shuwaikh Industrial lies in Kuwait governorate and houses factories and logistics warehouses that rely on continuous tank water supply.
We test pressure at each main distribution point to ensure uniform flow across all sectors.
Tank size and pipe run checked before any pump is chosen
Type and capacity matched to actual tank height and demand
Pump seated on isolation pads to stop vibration reaching the structure
Inlet and discharge lines fitted with non-return and isolation valves
Outlet pressure measured and confirmed stable under normal fixture load
All joints inspected for leaks before the job is signed off
How we work

Tell us what is happening and where, and the right equipment is loaded before we arrive.

We film the line from inside and know the kind of blockage and its exact place. No guessing.

High pressure water, a machine or a drain snake, whichever the line actually needs.

The camera runs a second pass and you see the line clear with your own eyes before we leave.
Same method, same equipment. Only the size of the job changes.




Why us
Amana means trust. Someone else's home is not ours to be careless in.
Do not take our word for it. Look at the line yourself.
Breaking is the last resort, never the first step.
A blocked line does not wait for the morning.
Six governorates, 139 areas.
For buildings and complexes, servicing before the problem starts.
Restaurants, offices and complexes, not only homes.
Common questions
Need someone now? The emergency line is open any hour.
+965 9668 4964
One pump suffices if the tank sits on one roof section. If the roof is partitioned or multiple roofs exist, we recommend one pump per tank to prevent severe pressure loss.
The pump stops immediately and remaining water in the lines drains down. We fit a one-way valve on the outlet line to stop water from backing into the tank when the pump halts.