Site and depth planning
Position and depth chosen to suit the transfer pump and surface loads

Farwaniya
An underground tank in Ardhiya near the industrial zone is built accounting for neighbourhood noise and shifting sand soil. We reinforce walls with additional support columns, insulate against moisture and airborne salts, and leak-test with a full-day fill cycle.
Ardhiya villas near the industrial zone face unique challenges from saline groundwater and fine sand. The sandy soil here does not support heavy load well, so we place a thick cement base under the tank and install rows of concrete columns instead of thin walls. Salinity in the air and groundwater corrodes concrete, so we use salt-resistant cement and add extra insulation on outer walls.
Ardhiya is in Farwaniya governorate near the industrial zone, a residential area with specific soil and salinity conditions.
We test groundwater salinity before starting because high salt content requires thicker insulation on walls.
Position and depth chosen to suit the transfer pump and surface loads
Base and walls built to carry soil pressure and full water load
Internal and external coating layers that block water movement in both directions
Inlet and outlet openings sealed with rubber collars to prevent pipe-joint leaks
Transfer pump and water-level float wired and adjusted for correct operation
Tank filled and water level watched to confirm zero leakage before backfilling
How we work

Tell us what is happening and where, and the right equipment is loaded before we arrive.

We film the line from inside and know the kind of blockage and its exact place. No guessing.

High pressure water, a machine or a drain snake, whichever the line actually needs.

The camera runs a second pass and you see the line clear with your own eyes before we leave.
Same method, same equipment. Only the size of the job changes.




Why us
Amana means trust. Someone else's home is not ours to be careless in.
Do not take our word for it. Look at the line yourself.
Breaking is the last resort, never the first step.
A blocked line does not wait for the morning.
Six governorates, 139 areas.
For buildings and complexes, servicing before the problem starts.
Restaurants, offices and complexes, not only homes.
Common questions
Need someone now? The emergency line is open any hour.
+965 9668 4964
Yes significantly. We remove fine sand to approximately one meter depth and pour a thick concrete base on compacted gravel to spread the load evenly.
Yes, salt penetrates ordinary concrete and causes gradual corrosion. We use salt-resistant cement and thick plastic sheeting on all outer surfaces for long-term protection.