Copper or steel pipe run
Correct diameter pipe sized to kitchen appliance load and inlet pressure.

Farwaniya
A kitchen gas line in Rai Industrial must withstand heavy-use pressures in hotels and restaurants. We fix pipes with heavy clamps, test high pressure, and document each test step.
Rai Industrial has big hotels, commercial towers and restaurants with massive kitchens running multiple appliances. The gas line here carries high volume under continuous high pressure, so pipes must be thick and clamped every 60 centimetres minimum with metal brackets. We test by running each appliance one at a time and then all together to confirm pressure holds steady even at peak load.
Rai Industrial Area is in Farwaniya governorate, adjacent to The Avenues Mall, where major hotels and commercial facilities concentrate.
We test the main line at 250 millibars for 15 minutes and transfer test data to the building's scheduled maintenance system.
Correct diameter pipe sized to kitchen appliance load and inlet pressure.
Individual outlet with isolation valve for each hob, oven or fryer.
Pipe run inside protective conduit or channel with ventilation clearance observed.
Joints finished by brazing or press-fit method suited to the pipe material.
Nitrogen pumped to test pressure and held to confirm every joint is tight.
Inspection of an existing run and repair of any corroded section or weeping joint.
How we work

Tell us what is happening and where, and the right equipment is loaded before we arrive.

We film the line from inside and know the kind of blockage and its exact place. No guessing.

High pressure water, a machine or a drain snake, whichever the line actually needs.

The camera runs a second pass and you see the line clear with your own eyes before we leave.
Same method, same equipment. Only the size of the job changes.




Why us
Amana means trust. Someone else's home is not ours to be careless in.
Do not take our word for it. Look at the line yourself.
Breaking is the last resort, never the first step.
A blocked line does not wait for the morning.
Six governorates, 139 areas.
For buildings and complexes, servicing before the problem starts.
Restaurants, offices and complexes, not only homes.
Common questions
Need someone now? The emergency line is open any hour.
+965 9668 4964
Floor height does not directly affect pressure, but line length from inlet to appliances needs exact calculation. We step up pressure from the regulator down the pipes to the third floor and test there. If loss is significant, we increase bore or fit a secondary regulator near the kitchen.
We insist there must be one recognized inlet point certified by the regulator, and inlet pressure must match the specifications for the entire line. If an outside supplier connects without checks, they risk overpressure or mismatch. We coordinate with all parties and retest the line after any new connection.