Main pipe run
Running the supply line into the kitchen at the correct pipe diameter

Farwaniya
Jleeb Al-Shuyoukh restaurants vary widely in size and layout, many needing complex gas networks for heavy cooking. We run tube from the main gas meter to every cooking appliance and test the entire network under safe pressure.
Jleeb Al-Shuyoukh is a dense market with old packed buildings and relatively low kitchen ceilings, meaning gas lines often run over cooks' heads. We choose routes clear of hot airflow and steam, and fix them with sturdy brackets to handle vibration from heavy equipment. Each restaurant has its own meter and an emergency isolation valve near the exit.
Jleeb Al-Shuyoukh is in Farwaniya governorate, an active market zone where dozens of restaurants, cafés and shops crowd the streets.
We pressure-test gas lines in Jleeb markets at 15 bar for a full hour because heavy appliances cause constant vibration.
Running the supply line into the kitchen at the correct pipe diameter
Dedicated branch for each burner, oven, grill or fryer in the kitchen
Valve at each appliance so one unit can be isolated without stopping the whole line
Pipes run inside the wall or surface-mounted to suit the building structure
Completed network tested under dry nitrogen pressure before any appliance is connected
Inspecting or extending a working kitchen gas network with minimal downtime
How we work

Tell us what is happening and where, and the right equipment is loaded before we arrive.

We film the line from inside and know the kind of blockage and its exact place. No guessing.

High pressure water, a machine or a drain snake, whichever the line actually needs.

The camera runs a second pass and you see the line clear with your own eyes before we leave.
Same method, same equipment. Only the size of the job changes.




Why us
Amana means trust. Someone else's home is not ours to be careless in.
Do not take our word for it. Look at the line yourself.
Breaking is the last resort, never the first step.
A blocked line does not wait for the morning.
Six governorates, 139 areas.
For buildings and complexes, servicing before the problem starts.
Restaurants, offices and complexes, not only homes.
Common questions
Need someone now? The emergency line is open any hour.
+965 9668 4964
Yes, but the total gas load must be recalculated and we must verify the main pipe bore is adequate. If it is saturated, we upgrade it or run a separate line from the meter.
A test certificate proves the network passed pressure and leak-detection checks. Municipal and civil defense authorities may demand it for licensing, so we keep records and hand them over with other documentation.