Cold water supply
PPR runs to every tap, cistern and appliance point in the unit

Ahmadi
Apartment pipe runs in Abu Halifa extend supply lines from the area's central well through main risers to every building. We install properly sized pipes and pressure-test each storey after initial connection, before plastering and finishing begin.
Abu Halifa apartment buildings enjoy reliable water supply from the area's central station, but pressure fluctuates during peak hours. Pipe design must tolerate pressure swings from eight to twenty-five bars across a single day. We fit pressure-regulation valves at each building to lock internal pressure at sixteen bars, and recommend a separate rooftop tank if the riser exceeds seven storeys. Initial testing happens immediately after the main riser is connected, running all taps on each floor simultaneously to check balance.
Abu Halifa adjoins Abu Halifa Co-op and lies near Ahmadi Town, a mixed industrial and residential district.
Pressure valves are tested under full load because valve failures only surface during sustained high flow.
PPR runs to every tap, cistern and appliance point in the unit
uPVC drain lines graded to prevent standing water and blockages
Waste and supply stubs positioned accurately before screed is poured
Supply and waste points for sink, washing machine and refrigerator
Recorded pressure test on the supply network before walls are closed
Connecting the unit's supply line to the building tank and pump system
How we work

Tell us what is happening and where, and the right equipment is loaded before we arrive.

We film the line from inside and know the kind of blockage and its exact place. No guessing.

High pressure water, a machine or a drain snake, whichever the line actually needs.

The camera runs a second pass and you see the line clear with your own eyes before we leave.
Same method, same equipment. Only the size of the job changes.




Why us
Amana means trust. Someone else's home is not ours to be careless in.
Do not take our word for it. Look at the line yourself.
Breaking is the last resort, never the first step.
A blocked line does not wait for the morning.
Six governorates, 139 areas.
For buildings and complexes, servicing before the problem starts.
Restaurants, offices and complexes, not only homes.
Common questions
Need someone now? The emergency line is open any hour.
+965 9668 4964
Only if the riser exceeds seven storeys or if central pressure is erratic. Six floors or fewer usually work with direct pressure and a regulating valve.
We run cold and hot lines together and verify strong flow from every tap on the tenth floor. If flow is weak, a manometer measures pressure and we decide whether a pump is needed.
