Hot and cold supply points
PPR lines routed precisely to basin, shower and toilet positions

Capital
Bathroom rough-in in Salhiya requires running hot and cold lines from the roof tank or pump to every point before walls go up. We connect waste with secure traps, test pressure and flow under full load before the ceiling closes.
Salhiya commercial blocks near the Sheraton have individual roof tanks per unit, meaning the hot water line needs either a heat exchanger in the upper floor or an insulated pipe. We measure the distance from tank to the furthest tap and calculate heat loss and pressure drop. Waste pipes run alongside the cold supply but in a separate channel so heat does not affect them.
Salhiya in Kuwait governorate near the Commercial Complex and Sheraton is an area of high-rise blocks with mixed residential and commercial units.
Before handover we open all taps together and monitor hot water pressure for five minutes because pressure drop signals a heat exchanger fault.
PPR lines routed precisely to basin, shower and toilet positions
uPVC drain runs laid at correct fall to prevent standing water
Floor trap levels set before screed to align flush with final tiling
Connecting the waste run to the vent stack prevents trap siphoning and odour
Documented pressure test on supply lines before walls are permanently closed
All supply and waste point locations recorded for finishing and future maintenance
How we work

Tell us what is happening and where, and the right equipment is loaded before we arrive.

We film the line from inside and know the kind of blockage and its exact place. No guessing.

High pressure water, a machine or a drain snake, whichever the line actually needs.

The camera runs a second pass and you see the line clear with your own eyes before we leave.
Same method, same equipment. Only the size of the job changes.




Why us
Amana means trust. Someone else's home is not ours to be careless in.
Do not take our word for it. Look at the line yourself.
Breaking is the last resort, never the first step.
A blocked line does not wait for the morning.
Six governorates, 139 areas.
For buildings and complexes, servicing before the problem starts.
Restaurants, offices and complexes, not only homes.
Common questions
Need someone now? The emergency line is open any hour.
+965 9668 4964
Absolutely, because the distance from the roof tank to the bathroom may exceed 20 metres. We wrap pipes in foam or mineral wool insulation to cut heat loss and ensure actual hot water reaches the tap.
We install a small electric heat exchanger beside the bathroom or run a hot line from the ground floor if there is a heat pump. Either way needs a separate flow test.