Hot and cold supply
PPR runs sized for sink, dishwasher and fridge-water connections

Hawalli
Kitchen first-fix in the Ministries Area means running supply, waste and vent lines through tight spaces before walls close. We map the routes, set pressure and test every joint before drywall goes up. These modern flats demand precision layout to avoid clashing with structural columns and electrical chases. All connections are tested under load before any finishing materials arrive.
High-rise residential and government towers around the Ministry complex have kitchens laid out to tight specifications, with pipework squeezed between structural pillars and live electrical conduits. We measure floor-to-soffit height, fall distance to waste stack and headroom for the P-trap before any boxing-in. If the trap sits too shallow we raise it before drywall closes around it. The vent stack position must clear upper cabinet runs, which we verify before first-fixing begins.
The Ministries Area in Hawalli is a modern administrative and residential zone where kitchen layouts demand precise pre-closure pipe planning.
Every waste line we set in this area runs hot and cold water together under full flow because walls close within hours.
PPR runs sized for sink, dishwasher and fridge-water connections
uPVC drain at correct fall to stop grease settling inside the pipe
Grease trap position and vent stack stub to block sewer odour entry
Gas supply stub-out to cooker position run before wall cladding closes
Supply and drain stub prepared at the right height for the water heater
Recorded pressure test on all supply lines before any wall is closed
How we work

Tell us what is happening and where, and the right equipment is loaded before we arrive.

We film the line from inside and know the kind of blockage and its exact place. No guessing.

High pressure water, a machine or a drain snake, whichever the line actually needs.

The camera runs a second pass and you see the line clear with your own eyes before we leave.
Same method, same equipment. Only the size of the job changes.




Why us
Amana means trust. Someone else's home is not ours to be careless in.
Do not take our word for it. Look at the line yourself.
Breaking is the last resort, never the first step.
A blocked line does not wait for the morning.
Six governorates, 139 areas.
For buildings and complexes, servicing before the problem starts.
Restaurants, offices and complexes, not only homes.
Common questions
Need someone now? The emergency line is open any hour.
+965 9668 4964
We use a laser level to measure the difference between the basin outlet and the stack connection point. The gradient must be 25 to 50 mm per metre to avoid pooling. We test with real flow before sign-off.
No, because the units will be wall and floor-fixed by then. The P-trap height must be set right before closing if it sits shallow. Delaying this means opening walls later and breaking tiles.