Hot and cold supply
PPR runs sized for sink, dishwasher and fridge-water connections

Hawalli
Kitchen-first-fix in Shaab requires checking where the kitchen sits relative to roof tanks and upper floors. Supply lines run easily enough, but the kitchen waste needs enough height to fall toward the main stack. Full flow is tested before any wall closes.
Shaab houses near Sha'ab Leisure Park are mostly older villas with cramped side kitchens or newer homes with remodeled kitchens including a centre island. Old villas have tight waste stacks and a modern island needs a central waste run with sturdy pipes that clear the cabinet base. We measure floor cavities and choose pipe diameter that allows slope and smooth operation.
Shaab sits in Hawalli governorate, a historic waterfront area mixing older and newer residential buildings.
Waste lines run under the slab with at least five centimetres clearance from the bottom reinforcement to prevent cracking.
PPR runs sized for sink, dishwasher and fridge-water connections
uPVC drain at correct fall to stop grease settling inside the pipe
Grease trap position and vent stack stub to block sewer odour entry
Gas supply stub-out to cooker position run before wall cladding closes
Supply and drain stub prepared at the right height for the water heater
Recorded pressure test on all supply lines before any wall is closed
How we work

Tell us what is happening and where, and the right equipment is loaded before we arrive.

We film the line from inside and know the kind of blockage and its exact place. No guessing.

High pressure water, a machine or a drain snake, whichever the line actually needs.

The camera runs a second pass and you see the line clear with your own eyes before we leave.
Same method, same equipment. Only the size of the job changes.




Why us
Amana means trust. Someone else's home is not ours to be careless in.
Do not take our word for it. Look at the line yourself.
Breaking is the last resort, never the first step.
A blocked line does not wait for the morning.
Six governorates, 139 areas.
For buildings and complexes, servicing before the problem starts.
Restaurants, offices and complexes, not only homes.
Common questions
Need someone now? The emergency line is open any hour.
+965 9668 4964
Yes, if the slab has an architectural void or if thickness allows a narrow channel. We check depth and available fall first, and if it is short we relocate the sink to an exterior wall instead of the island.
We install a second waste stack beside the old one, either linking it on the ground floor or in the external trench. This spreads the load and is usually cheaper than rebuilding a load-bearing wall.
