Tank installation
Mounting the tank on a level concrete base to protect its base from cracking

Farwaniya
Roof tank installation in Abdullah Mubarak requires tracing water supply from the municipality line under the street. We raise the pipe through the building wall, set the tank on the roof and adjust the float valve to auto-cut. We run the system under full pressure and record meter readings before handover.
Abdullah Mubarak has modern villas with thick insulated roofs. The tank usually sits beside external stairs or in a corner away from bedrooms. The challenge here is that most buildings sit far from the municipality meter, so we need a long rising pipe from the street to the roof. We size the pipe to compensate for pressure loss over the distance. Overflow we drop to a roof trap or the main drain line.
Abdullah Mubarak in Farwaniya governorate near Abdullah Mubarak Co-op is an area of modern villas experiencing steady residential expansion.
We record the initial meter reading and measure static pressure before filling the tank because street pressure varies by time of day.
Mounting the tank on a level concrete base to protect its base from cracking
Running the fill line and distribution line to floors in PPR pipe
Installing the overflow at correct slope so no water pools on the roof
Connecting the existing transfer or pressure pump and setting its switch
Fitting a brass float valve sized to the tank for accurate fill cut-off
Testing all joints under pressure before handover to confirm no leaks
How we work

Tell us what is happening and where, and the right equipment is loaded before we arrive.

We film the line from inside and know the kind of blockage and its exact place. No guessing.

High pressure water, a machine or a drain snake, whichever the line actually needs.

The camera runs a second pass and you see the line clear with your own eyes before we leave.
Same method, same equipment. Only the size of the job changes.




Why us
Amana means trust. Someone else's home is not ours to be careless in.
Do not take our word for it. Look at the line yourself.
Breaking is the last resort, never the first step.
A blocked line does not wait for the morning.
Six governorates, 139 areas.
For buildings and complexes, servicing before the problem starts.
Restaurants, offices and complexes, not only homes.
Common questions
Need someone now? The emergency line is open any hour.
+965 9668 4964
Yes, but we put a one-way valve in the supply pipe to stop roof water flowing back to the ground tank. We test the valve under pressure to confirm it seals fully when the pump stops.