Main pipe run
Running the supply line into the kitchen at the correct pipe diameter

Mubarak Al-Kabeer
A restaurant gas network in Abu Hasaniya starts at the inlet meter on the villa wall and extends to the kitchen and outdoor grill. We select fittings and valves for the pressure rating and secure them to interior and exterior walls. Pressure and leak testing is done with a test cylinder and digital gauge before operation.
A villa near Abu Hasaniya Co-op is often two-storey with exterior walls exposed to sea air. Outside pipes on these walls need corrosion-resistant materials and protective coating every two years. The interior kitchen usually sits below air conditioning units, so the gas line routes away from AC vents to prevent unexpected pressure cooling.
Abu Hasaniya sits in Mubarak Al-Kabeer governorate and features large sea-facing villas with spacious kitchens and outdoor grill areas.
Joints and valves are tested at 1.5 times normal operating pressure to ensure no failure.
Running the supply line into the kitchen at the correct pipe diameter
Dedicated branch for each burner, oven, grill or fryer in the kitchen
Valve at each appliance so one unit can be isolated without stopping the whole line
Pipes run inside the wall or surface-mounted to suit the building structure
Completed network tested under dry nitrogen pressure before any appliance is connected
Inspecting or extending a working kitchen gas network with minimal downtime
How we work

Tell us what is happening and where, and the right equipment is loaded before we arrive.

We film the line from inside and know the kind of blockage and its exact place. No guessing.

High pressure water, a machine or a drain snake, whichever the line actually needs.

The camera runs a second pass and you see the line clear with your own eyes before we leave.
Same method, same equipment. Only the size of the job changes.




Why us
Amana means trust. Someone else's home is not ours to be careless in.
Do not take our word for it. Look at the line yourself.
Breaking is the last resort, never the first step.
A blocked line does not wait for the morning.
Six governorates, 139 areas.
For buildings and complexes, servicing before the problem starts.
Restaurants, offices and complexes, not only homes.
Common questions
Need someone now? The emergency line is open any hour.
+965 9668 4964
Copper is vulnerable to sea salt in high humidity. We use steel pipe with epoxy coating externally, or nickel-plated copper if you insist on copper. We inspect the coating every two years.
No, safety codes require gas lines to be visible. We run them on the wall surface or in open floor chases so inspection, maintenance and quick repair are possible if a leak occurs.
