Hot and cold supply
PPR runs sized for sink, dishwasher and fridge-water connections

Farwaniya
Kitchen first-fix in Ishbiliya starts with careful survey of available space and marking all service points. We lay hot water, cold water, waste and vent lines in logical sequence then test pressure before closing any walls.
Ishbiliya is a family area with traditional kitchens opening onto interior courtyards, where the main floor traps and roof tanks usually sit. We plan supply lines coming from the roof tank and direct them to the sink using copper or plastic pipes per local standards. The waste line slopes steadily toward the floor trap and includes an inspection point mid-route for future maintenance.
Ishbiliya is located in Farwaniya governorate and is a family residential area organised around shared courtyards.
Every solder joint on copper lines is tested before closure to ensure no weeping occurs at critical points.
PPR runs sized for sink, dishwasher and fridge-water connections
uPVC drain at correct fall to stop grease settling inside the pipe
Grease trap position and vent stack stub to block sewer odour entry
Gas supply stub-out to cooker position run before wall cladding closes
Supply and drain stub prepared at the right height for the water heater
Recorded pressure test on all supply lines before any wall is closed
How we work

Tell us what is happening and where, and the right equipment is loaded before we arrive.

We film the line from inside and know the kind of blockage and its exact place. No guessing.

High pressure water, a machine or a drain snake, whichever the line actually needs.

The camera runs a second pass and you see the line clear with your own eyes before we leave.
Same method, same equipment. Only the size of the job changes.




Why us
Amana means trust. Someone else's home is not ours to be careless in.
Do not take our word for it. Look at the line yourself.
Breaking is the last resort, never the first step.
A blocked line does not wait for the morning.
Six governorates, 139 areas.
For buildings and complexes, servicing before the problem starts.
Restaurants, offices and complexes, not only homes.
Common questions
Need someone now? The emergency line is open any hour.
+965 9668 4964
We choose a route under floor or along outside walls and maintain a steady fall of one centimetre per metre. If the run is very long we propose adding an intermediate inspection chamber to ease cleaning.
Yes, but PVC pipes must be reliable grade and rated for home water pressure. We use locally standard fittings and connections for safety and long-term maintenance.