Waste outlet check
Height and position confirmed before the shower tray is set.

Farwaniya
Shower installation in Khitan Al-Jadida starts by measuring the space and finding a structural wall to anchor the head and set the drain fall. We run hot and cold supply, secure the body with heavy anchors into concrete, then test flow and seal before any tiling begins.
Most Khitan Al-Jadida villas have spacious en-suite bathrooms with solid concrete walls and flat floors, meaning the shower body can be anchored firmly without risk of cracks. We scan the wall first with a detector and tap it to confirm concrete depth, then drill anchor holes at the correct angle. The fall from shower head to floor trap is usually already there, but we verify the floor pitch and add traps where needed.
Khitan Al-Jadida is in Farwaniya governorate, a modern villa district with regular drainage patterns and strong structural support.
After the body is fixed, water is drained at full volume for two minutes with no pooling around the base.
Height and position confirmed before the shower tray is set.
Tray levelled and trap sealed with a rubber gasket.
Hot and cold lines connected to the mixer with isolation valves.
Mixer and arm fitted with thread sealant on every joint.
All tray-to-wall edges sealed with non-fungal sanitary silicone.
Water run and full drainage confirmed before handover.
How we work

Tell us what is happening and where, and the right equipment is loaded before we arrive.

We film the line from inside and know the kind of blockage and its exact place. No guessing.

High pressure water, a machine or a drain snake, whichever the line actually needs.

The camera runs a second pass and you see the line clear with your own eyes before we leave.
Same method, same equipment. Only the size of the job changes.




Why us
Amana means trust. Someone else's home is not ours to be careless in.
Do not take our word for it. Look at the line yourself.
Breaking is the last resort, never the first step.
A blocked line does not wait for the morning.
Six governorates, 139 areas.
For buildings and complexes, servicing before the problem starts.
Restaurants, offices and complexes, not only homes.
Common questions
Need someone now? The emergency line is open any hour.
+965 9668 4964
Yes, if the interior wall is solid concrete with sufficient thickness. We scan it with a detector first to rule out electrical or waste pipes behind it. If thickness is marginal we recommend a treated timber backing board.
We run a sloping waste line from the shower to the trap beneath the floor or along an outer wall if exposed. We test the fall with a level and check for sag points in the pipe. If the run is long we may need an intermediate trap.
