Position and height
correct mounting height marked before any fixing begins

Farwaniya
Washbasin installation in Khitan Al-Jadida requires opening the bathroom wall or floor to run the supply and waste pipes inside. We choose the height to suit the household, extend pipes from the main water line and connect the drain to the main stack. Every joint is tested before closing the wall or floor.
New Khitan houses often have modern layouts with horizontal pipe runs under the bathroom floor. The main stack sits far from where the basin must go, so we run new pipes under tiles with a steady fall toward the stack. We check the house plans to trace existing pipework before cutting, because hitting an active water or waste line delays the job significantly.
Khitan Al-Jadida lies in Farwaniya governorate, a new residential area where most families ask for a second basin in an en-suite or guest bathroom.
Water pressure at the outlet and the waste pipe fall are checked with a level before handover.
correct mounting height marked before any fixing begins
drain slope set and trap fitted with a proper water seal
hot and cold supply connected through new isolation valves
sanitary silicone applied at the basin edge to block water ingress
mixer seated and cartridge aligned to stop dripping at rest
water run and every joint checked before wall or cabinet is closed
How we work

Tell us what is happening and where, and the right equipment is loaded before we arrive.

We film the line from inside and know the kind of blockage and its exact place. No guessing.

High pressure water, a machine or a drain snake, whichever the line actually needs.

The camera runs a second pass and you see the line clear with your own eyes before we leave.
Same method, same equipment. Only the size of the job changes.




Why us
Amana means trust. Someone else's home is not ours to be careless in.
Do not take our word for it. Look at the line yourself.
Breaking is the last resort, never the first step.
A blocked line does not wait for the morning.
Six governorates, 139 areas.
For buildings and complexes, servicing before the problem starts.
Restaurants, offices and complexes, not only homes.
Common questions
Need someone now? The emergency line is open any hour.
+965 9668 4964
Yes, the waste must drop to the main stack usually on the ground floor. We run it inside walls with a steady fall the whole way so water does not collect or back up.
Yes if the new location is close to the stack or the old pipes can be reused. If it is far away, we cap the old pipes and run new ones under the tiles with the correct fall.