Waste outlet check
Height and position confirmed before the shower tray is set.

Ahmadi
Shower installation at Zour requires strong thermal insulation because the power plant radiates intense heat. We select foam-insulated piping, map water routes to avoid excess heat and test water temperature at the shower head.
Worker bathrooms at Zour power station sit near cooling towers and furnaces, with walls and ceilings running very hot year-round. We run cold water lines through insulated pipes under the floor to avoid losing coolness before reaching the shower. The hot water line stays close to the steam condenser so it holds a stable temperature.
Zour lies in Ahmadi governorate, a power and desalination station where high heat and constant pressure burden water systems.
Water temperature at the shower outlet is measured after one hour of running because ambient heat affects warm water stability.
Height and position confirmed before the shower tray is set.
Tray levelled and trap sealed with a rubber gasket.
Hot and cold lines connected to the mixer with isolation valves.
Mixer and arm fitted with thread sealant on every joint.
All tray-to-wall edges sealed with non-fungal sanitary silicone.
Water run and full drainage confirmed before handover.
How we work

Tell us what is happening and where, and the right equipment is loaded before we arrive.

We film the line from inside and know the kind of blockage and its exact place. No guessing.

High pressure water, a machine or a drain snake, whichever the line actually needs.

The camera runs a second pass and you see the line clear with your own eyes before we leave.
Same method, same equipment. Only the size of the job changes.




Why us
Amana means trust. Someone else's home is not ours to be careless in.
Do not take our word for it. Look at the line yourself.
Breaking is the last resort, never the first step.
A blocked line does not wait for the morning.
Six governorates, 139 areas.
For buildings and complexes, servicing before the problem starts.
Restaurants, offices and complexes, not only homes.
Common questions
Need someone now? The emergency line is open any hour.
+965 9668 4964
Thick foam-insulated pipes maintain water coolness within about one degree of source. If insulation is insufficient we suggest storing water in an underground tank far from heat sources.
We fit a thermostatic mixing valve that holds a steady temperature between hot and cold water. The valve opens and closes automatically to protect workers from water exceeding 45 degrees.